Home / Products / Cables & assemblies / MPO trunk cables
MPO trunk cable with US Conec MTP legs
72F singlemode trunk, 6 x MPO-12 APC unpinned legs each end; End A under a braided pulling grip, End B fanned out.
72F singlemode trunk, 6 x MPO-12 APC unpinned legs each end; End A under a braided pulling grip, End B fanned out.Braided pulling grip with eye over staggered connector pairs.
MPOBuilt to lengthBABA compliant

MPO Trunk Cables

MPOT- · 12 to 288F · MPO-12 / MPO-24 · Corning SMF-28 Ultra APC · OM4 / OM5 UPC · built to length

Pre-terminated MPO backbone between panels, cassettes and enclosures in one factory-terminated assembly. Each trunk is built to the length you order, with fiber count, leg type, pinning, polarity, jacket rating and pulling grip chosen per order.

12–288Fibers per trunk
A / B / CPolarity types
100%End faces tested
Build your part numberMPOT-[legs]X[fibers]-[ends]-[polarity]-[fiber]-[jacket]-[grip]-[NNN]F
Standard: 36 in breakout both ends, legs under a grip staggered in pairs. Custom breakout or stagger is noted on the quote.
PDF Get the DatasheetRequest a Quote
OverviewPolarityFiber countsSpecificationsOrderingCompatibleDatasheetQuote
Overview

Pre-Terminated MPO Backbone, Cut to Your Run

Singlemode trunks use APC polished US Conec MTP connectors on Corning SMF-28 Ultra singlemode fiber (G.652.D and G.657.A1 compliant, bend-insensitive). OM4 and OM5 multimode trunks use 50/125 µm laser-optimized fiber with UPC (flat) US Conec MTP connectors for 40G to 400G parallel-optic links, on OM4 or OM5 ribbon cable (aqua or lime green jacket). Multimode reach: 40G-SR4 150 m; 100G-SR4 and 400G-SR8 100 m; 400G-SR4.2 100 m on OM4, 150 m on OM5. OM3 on request. The standard cable is a yellow indoor plenum (OFNP) ribbon cable.

  • 12 to 288 fibers in MPO-12 or MPO-24 legs
  • Built to length, ordered in feet
  • OM4 or OM5 multimode, UPC (flat); singlemode APC
  • Pinned or unpinned at each end, key up
  • All polarity types: Type A, B or C
  • Braided pulling grip with eye: End A, End B, both or none
  • Staggered legs under the grip for a slim pull
  • Jacket: plenum (OFNP) standard; LSZH or riser (OFNR) on request
  • Labeled End A and End B, legs numbered
  • Applications: data center and building backbone, row-to-row and room-to-room MPO runs
Pulling grip over staggered legs.

Pulling grip over staggered legs.

Polarity

Type a, B or C

Every link has to carry each transmitter to a receiver at the far end. The polarity type sets which fiber position at End A lands on which position at End B. All three types are available on our MPO jumpers and trunks.

TypeMapKeys
AStraight through: 1 to 1Key up to key down
BReversed: 1 to 12Key up to key up
CPairs flipped: 1 to 2, 2 to 1Key up to key down

Two Quick Checks

  • Count the flips. Between two MPO transceivers, the number of Type B jumpers and trunks in the link must be odd (1 or 3).
  • Pinned meets unpinned. Every mated MPO pair is one pinned and one unpinned connector. Transceivers and our cassette rear ports are pinned, so the cords that plug into them are unpinned.
  • Method B / Universal for new builds: Type B trunk with MPC-24-LC-U cassettes at both ends.
  • Not sure? Send us both ends of the link and we will specify the polarity.
Fiber Count Builds

Legs per End

Total FibersMPO-12 Legs per EndMPO-24 Legs per End
121–
2421
363–
4842
7263
9684
144126
192168
2882412

Trunk Cable

FibersCableNominal ODBend Radius, Install / InstalledGrip ODMin. Conduit
12–4812F ribbon, central tube0.38 in7.6 / 3.8 in1.0 in2 in
72, 9612F ribbon, central tube0.49 in9.8 / 4.9 in1.25 in2 in
14412F ribbon, central tube0.61 in12.2 / 6.1 in1.5 in2 in
192, 28824F ribbon, split to 12F0.78 in11.7 / 7.8 inup to 2.0 in2 in; 3 in recommended

Nominal values for the standard yellow OFNP ribbon cable; LSZH and OFNR can differ. Bend radius: during installation (under pulling load) / installed (long-term), per the cable manufacturer. Max pulling load 100 lbf on the grip.

Specifications

Specifications

Fiber, SinglemodeCorning SMF-28 Ultra, G.652.D / G.657.A1
Fiber, MultimodeOM4 or OM5 50/125 µm laser-optimized; OM5 wideband (WBMMF)
Fiber Count12 to 288
ConnectorMPO-12 or MPO-24 (US Conec MTP), pinned or unpinned, key up
PolishAPC (singlemode); UPC, flat (multimode)
PolarityType A, B or C, leg to leg
Insertion Loss, Standard MPO0.75 dB singlemode, 0.60 dB multimode max per mated pair
Insertion Loss, Low-Loss MPO0.35 dB max per mated pair
Return LossSinglemode APC 60 dB min; multimode 20 dB min
Trunk CableIndoor plenum (OFNP) ribbon, round, yellow; LSZH or OFNR on request
Color CodeSinglemode: yellow jacket and legs, green connectors; OM4: aqua jacket, violet connectors; OM5: lime green jacket, aqua connectors
Legs0.12 in [3.0 mm] round, yellow
Breakout Length36 in standard; custom on request
Pulling GripBraided with eye; 100 lbf max pull
Length Tolerance+4 in / −0 up to 33 ft; +1% / −0 over 33 ft
Operating Temperature14 to 158 °F
ComplianceBuild America, Buy America (BABA) compliant, self-certified. Compliance letter available on request.
DocumentationTest data and certificate of conformance available on request.

Installation Notes

  • Pull by the pulling eye only, never by the legs or connectors
  • Keep dust caps on until the trunk is in place
  • Pull 100 lbf max on the grip; hold the bend radius in the cable table
  • Order length end face to end face; allow for slack, rises and drops
  • Confirm pinning and polarity against the cassettes at each end
Ordering

Example Configurations

Part NumberDescription
MPOT-2X12-FF-A-SM-P-G0-030F24F singlemode, 2 x MPO-12 APC unpinned each end, Type A, plenum, no grip, 30 ftQuote
MPOT-6X12-FF-B-SM-P-GA-150F72F singlemode, 6 x MPO-12 APC unpinned each end, Type B, plenum, grip on End A, 150 ftQuote
MPOT-12X12-FF-B-SM-R-GA-200F144F singlemode, 12 x MPO-12 APC unpinned each end, Type B, riser, grip on End A, 200 ftQuote
MPOT-12X12-FF-B-OM4-P-GA-100F144F OM4 multimode, 12 x MPO-12 UPC unpinned each end, Type B, plenum, grip on End A, 100 ftQuote
MPOT-3X24-MF-A-SM-Z-G2-100F72F singlemode, 3 x MPO-24 APC, pinned End A to unpinned End B, Type A, LSZH, grips both ends, 100 ftQuote
MPOT-24X12-FF-C-SM-P-GA-250F288F singlemode, 24 x MPO-12 APC unpinned each end, Type C, plenum, grip on End A, 250 ftQuote
MPOT-12X24-FF-B-OM5-R-G2-300F288F OM5 multimode, 12 x MPO-24 UPC unpinned each end, Type B, riser, grips both ends, 300 ftQuote
MPOT-12X24-FF-B-SM-R-G2-300F288F, 12 x MPO-24, Type B, riser, grips both ends, 300 ftQuote

Part number format: MPOT-[legs]X[fibers per leg]-[ends]-[polarity]-[fiber]-[jacket]-[grip]-[NNN]F. Ends FF/MF/MM; polarity A/B/C; fiber SM singlemode APC, OM4 or OM5 multimode UPC (OM3 on request); jacket Z LSZH, R OFNR, P OFNP; grip GA End A, GB End B, G2 both, G0 none; NNN = feet.

Compatible Products

Works With

Datasheet

Download the MPO Trunk Cables Datasheet

4-page PDF: construction, cable data, polarity, builds and ordering.

1. Enter your work email2. The PDF downloads right away
Send me occasional One Optics product updates (optional).

We’ll only use your email to send this datasheet and follow up on your request. We never sell or share your information. Privacy policy

PDF

Thanks, Your Download Has Started

If it didn't start:

Download One-Optics-MPO-Trunk-Cables-Datasheet.pdf

All datasheets →

Request a Quote

Quote This Trunk

The part number from the builder is filled in for you. Sales replies by email with pricing and lead time.

+1 (702) 337-2788 · sales@oneoptics.com

Sent to sales@oneoptics.com. Attach a BOM or drawing if you have one.

We’ll only use your information to respond to your request. We never sell or share your information. Privacy policy

Related

You May Also Need